Mechanical blind motor
Secure setting of the end positions using self-locking push buttons. Easy programming of the end positions in either direction of rotation.
The motor is equipped with an overrun limit switch. This acts as an “emergency stop button” and protects the system from damage.
Auf Position
Full stop*
Auf Position
* Drive onto the overrun limit switch
| GJ56__ME (standard mechanical) | GJ5603k³ | GJ5606k | GJ5610 | GJ5620 | |
|---|---|---|---|---|---|
| Voltage | 230 V~/50 Hz | ||||
| Current | 0,40 A | 0,40 A | 0,60 A | 0,85 A | |
| Cos Phi | >0,95 | ||||
| Inrush current (factor) | x 1,2 | ||||
| Power output | 90 W | 93 W | 135 W | 190 W | |
| Torque | 3 Nm | 6 Nm | 10 Nm | 2 x 10 Nm | |
| Speed | 26 rpm | ||||
| Final cut-off range | 80 revolutions | ||||
| Protection class | IP 54 | ||||
| Overall length I (w. cpl.) | 299 mm | 299 mm | 309 mm | 336 mm | |
| Operating mode | S2 4 min. | ||||
| Sound pressure level | 34 db(a) | 34 db(a) | 35 db(a) | 40 db(a) | |
| Diameter | 55 mm | ||||
| weight | approx. 1.50 kg | approx. 1.50 kg | approx. 1.70 kg | approx. 2.20 kg | |
| Ambient humidity | dry, non-condensing | ||||
| Storage temperature | T = -15°C … +70°C | ||||
| Subject to technical changes. | |||||
| GJ56__ME (runtime-optimized version) | GJ5606 | GJ5616²³ |
|---|---|---|
| Voltage | 230 V AC / 50 Hz | |
| Current | 0,40 A | 0,70 A |
| Cos Phi | >0,95 | |
| Inrush current (factor) | × 1.2 | |
| Power output | 90 W | 150 W |
| Torque | 6 Nm | 2 x 8 Nm |
| Speed | 26 rpm | |
| Final cut-off range | 80 revolutions | |
| Protection class | IP 54 | |
| Overall length I (w. cpl.) | 304 mm | 336 mm |
| Operating mode | S2, 4 min. | |
| Sound pressure level¹ | 34 db(a) | 40 db(a) |
| Diameter | 55 mm | |
| weight | approx. 1.60 kg | approx. 2.20 kg |
| Ambient humidity | dry, non-condensing | |
| Storage temperature | T = -15°C .. +70°C | |
| Subject to technical changes. | ||
¹ The information on the average sound pressure level is for guidance only. The values were recorded at GEIGER at idle speed with the drive suspended freely at a distance of 1 m and averaged over 10 seconds. The measurement does not refer to a specific test stand.
² Without VDE and EMC test mark.
³ Without CCC mark of conformity.