Dual-Stop-Control

If an obstacle is detected downwards, the screen slightly moves up and makes two further attempts to reach the lower end position. After the last failed attempt, the motor moves the screen in the protection position.
If the obstacle is only present during the first or the second run, the screen will reach successfully the lower end position. So the motor can clearly distinguish between a real obstacle, such as a watering can, or a simple gust of wind.

If the screen moves up, the sensitivity is significantly reduced to ensure that the upper position can be reached safely though the wind has come up.

Obstacle detection in DOWN direction
Obstacle detection in DOWN direction
Blocking detection in UP direction
Blocking detection in UP direction

Wind resistance

The obstacle detection can reliably distinguish whether a resistance is an obstacle or a gust of wind. If the control system detects a gust of wind when moving in the UP direction, the screen is still moved safely to the upper end position. In this way, the system is protected and the screen is not damaged.

Wind resistance
Wind resistance

Features

SOC
SOLIDline-SOC
COM
SOLIDline-COM
ROC
SOLIDline-ROC

Technical data tubular motor SOLIDline with SOC motor head

GU4503 (3 Nm)
GU4506 (6 Nm)
GU4510 (10 Nm)
GU4520 (20 Nm)
GU4530 (30 Nm)
Voltage
230 V~/50 Hz
Current
0,35 A
0,36 A
0,47 A
0,63 A
0,80 A
Cos Phi
> 0,95
Incrush current (Factor)
x 1,2
Power
80 W
83 W
105 W
140 W
180 W
Torque
3 Nm
6 Nm
10 Nm
20 Nm
30 Nm
Speed of rotation
26 rpm
16 rpm
16 rpm
16 rpm
16 rpm
Protection class
IP44
Total length 1)
467,5 mm
509,5 mm
519,5 mm
549,5 mm
569,5 mm
Operation type
S2 4 min.
S2 4 min.
S2 4 min.
S2 5 min.
S2 4 min.
Sound pressure level 2)
39 dB(A)
39 dB(A)
39 dB(A)
41 dB(A)
41 dB(A)
Diameter
45 mm
Weight
ca. 1,70 kg
ca. 1,85 kg
ca. 1,90 kg
ca. 2,20 kg
ca. 2,40 kg
Air humidity
dry and non-condensing place
Storage temperature
T = -15°C .. +70°C
1) SOLIDline-ROC: + 5,9 mm / SOLIDline-COM: + 4,2 mm
2) The average sound pressure level data are intended for guidance only. The values were determined by GEIGER at a distance of 1 m, with a hanging motor at idle speed and averaged over 10 seconds. There is no reference to any specific test standard.
Subject to technical modifications. Please find information to the ambient temperature range of our GEIGER motors under www.geiger.de.